BXVCP - L-4919 A
- MSDS: BXVCP
- Manufacturer: LITTON INDUSTRIES INC ELECTRON DEVICES DIV
- Product Name: L-4919 A
- National Stock Number: 5960-00-812-9980
Product Identification
Product ID:L-4919 A
MSDS Date:08/15/1995
FSC:5960
NIIN:00-812-9980
MSDS Number: BXVCP
Responsible Party
WILLIAMSPORT, PA 17701
US
Emergency Phone: 717-326-3561
Info Phone: 717-326-3561
Preparer: MELISSA A. WITHCROW
Cage: 89146
Contractor
Telephone: 717-326-3561
Cage: 89146
Ingredients
MAGNETIZED MATERIAL
Hazards
LD50 LC50 Mixture:LD50 (ORAL, RAT) NOT RELEVANT
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NOT RELEVANT. NO HEALTH HAZARD. THIS
DEVICE IS AN ELECTRON TUBE WHICH CONTAINS A PERMANENT MAGNETIC
FIELD WHICH DOES NOT EXCEED THE LIMITS SPECIFIED IN 49 CFR
173.21(D).
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NONE
Medical Cond Aggravated by Exposure:NONE
First Aid
First Aid:NONE REQUIRED UNLESS TUBE IS BROKEN OR IN FIRE. GET MEDICAL
ATTENTION. INHALED:REMOVE TO FRESH AIR. PROVIDE CPR/OXYGEN IF
NEEDED. EYES:FLUSH WITH WATER FOR 15 MINUTES, HOLDING EYELIDS OPEN.
SKIN:WASH WITH SOAP & WATER. ORAL:NOT LIKELY TO OCCUR.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE DRY CHEMICAL. DO NOT USE WATER OR HALON AGENTS
ON FIRE.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING AND NIOSH-APPROVED
SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:ELECTRON TUBE MAY BURST FORMING TOXIC
FUMES.
Accidental Release
Spill Release Procedures:IF BROKEN, SWEEP UP CAREFULLY AND TRANSFER
INTO A SEALABLE WASTE CONTAINER. MINIMIZE GENERATION OF DUST.
Neutralizing Agent:NOT RELEVANT
Handling
Handling and Storage Precautions:STORE ELECTRON TUBES IN SAFE PLACE.
KEEP OUT OF REACH OF CHILDREN. PROTECT TUBES AGAINST PHYSICAL
DAMAGE.
Other Precautions:DO NOT CRUSH, GRIND, CUT, FILE, SAW OR OTHERWISE
CREATE DUST FROM MAGNETIC MATERIAL USED AS A PART OF ELECTRON
TUBES.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:ADEQUATE
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:EYE WASH STATION, QUICK DRENCH SHOWER AND
IMPERVIOUS CLOTHING
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES.
Supplemental Safety and Health
THE MANUFACTURER STATES THAT THIS ITEM IS CONSIDERED AN ARTICLE UNDER
OSHA 29 CFR 1910-1200(C). THIS PRODUCT IS SUITABLE FOR SHIPMENT VIA
MILITARY AIRCRAFT IF MAINTAINED A DISTANCE OF FIFTEEN (15) FEE T OR
MORE FROM COMPASS SENSING DEVICES.
Chemical Properties
HCC:M1
NRC/State Lic Num:NOT RELEVANT
Spec Gravity:NOT RELEVANT
Viscosity:NOT RELEVANT
Evaporation Rate & Reference:NOT RELEVANT
Solubility in Water:NOT RELEVANT
Appearance and Odor:SOLID FORM, ELECTRON TUBE
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:BREAKAGE, FIRE
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS. RECYCLING OF MAGNETS USED IN MICROWAVE
TUBES IS RECOMMENDED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.